Camp Far West Irrigation District — Daily Water Report

North Canal Diversion · Picovale Device M007949 · Report date: Thursday, September 3, 2026
North Ditch Gate
-1″
Set 9/1, 05:10 (unchanged)
Latest Meter Reading
0.00 cfs
Sep 3, 08:00 (Picovale) · 24-h avg ~0.0
Active Orders
0 cfs
AKT 0 + Bear River 0

1. Meter Flow, Orders by Source, Bear River Actual & Gate — Past Week

Hourly Picovale meter flow with the total order, the AKT and Bear River orders, Bear River's reported actual (from pump reports), and the implied AKT use (meter − Bear River actual; overflow not subtracted, so an upper bound) — all left axis in cfs — plotted against the North Ditch gate setting (right axis, inches), Aug 28 – Sep 3. Bear River actual and implied-AKT lines break where no pump report exists:

051015202530cfsgate″cfs (calib.)012345678910111213141520.2±0.99.6±0.415.1±0.622.8±1.013.2±0.60.9±0.32.9±0.17.7±0.413.7±0.114.6±0.718.5±5.126.0±0.926.6±0.127.5±1.16.2±0.411.2±0.419.3±0.825.9±0.524.5±0.621.1±1.024.1±0.517.6±0.516.3±0.528.6±1.224.1±0.71.1±0.427.0±1.525.8±1.21.0±0.40.22.65.07.426.729.131.5cfs ≈ 2.4×in -4.6bold=measured, italic=fitAug 28Aug 29Aug 30Aug 31Sep 1Sep 2Sep 3Picovale meter (cfs)Total order (cfs)AKT orderBear River orderBear River actual (reported)Overflow obs (visual, point est.)AKT est. use = meter − BR − overflow (point est.)

2. North Ditch Gate Setting

DateTimeGate (in)ChangeSet by
2026-09-0105:10-1Lowered from 13.5″ currentHenry
2026-08-2605:1013.5Raised from 12.2″Henry
2026-08-2505:1512.2Raised from -2″Henry
2026-08-2105:19-2Lowered from 10.5″Henry
2026-08-1908:4010.5Lowered from 12.4″Henry

3. Water Orders

SourceCFSEffective startEffective endNotes
AKT02026-09-01 07:00ongoingStands until changed
AKT02026-09-01 07:00ongoingStands until changed

Current standing orders total 0 cfs. Orders are due 24 h ahead of a 7am delivery.

4. Picovale Meter Level

At an unchanged -1″ gate, flow is holding near 0.0 cfs (24-h average), running essentially on order (about 0.0 cfs over). Selected hourly readings (full series in master.csv):

DateTimecfsDiverted (AF)Note
2026-09-0303:000.000.000
2026-09-0304:000.000.000
2026-09-0305:000.000.000
2026-09-0306:000.000.000
2026-09-0307:000.000.000
2026-09-0308:000.000.000Latest latest

Prior full day (9/2) diverted 0.1 AF over 24 hours.

5. Gate → Meter Response

The gate is at -1″ (set 9/1). Recent daily-average flow: 25.3 (8/30), 25.2 (8/31), 7.6 (9/1), 0.0 (9/2), 0.0 (9/3). The 24-h mean is 0.0 cfs with scatter min 0.0, max 0.0, SD 0.0 — supply is running essentially on order (about 0.0 cfs over).

Calibration: at the current -1″ the rating point is -1″ → 0.9 cfs (n=5). Fit: cfs ≈ 2.4×in -4.6, so 0 cfs → ~1.9″. The website gate calculator uses this regression.

6. Weekly Shareholder Notes

Space reserved for weekly notes to shareholders — announcements, reminders, or items for the next meeting. (Add notes here before publishing.)