Camp Far West Irrigation District — Daily Water Report

North Canal Diversion · Picovale Device M007949 · Report date: Thursday, June 25, 2026
North Ditch Gate
10.5″
Set 6/24, 05:18 (unchanged)
Latest Meter Reading
21.30 cfs
Jun 25, 06:00 (Picovale) · 24-h avg ~23.2
Active Orders
24 cfs
AKT 15 + Bear River 9

1. Meter Flow, Water Orders & Gate Setting — Past Week

Hourly Picovale flow and total active water orders (left axis, cfs) plotted against the North Ditch gate setting (right axis, inches), Jun 19 – Jun 25:

04812162024cfsgate″cfs (calib.)012345678910111220.2±0.99.6±0.415.1±0.622.8±1.013.2±0.60.9±0.32.9±0.17.7±0.413.7±0.114.6±0.723.2±0.817.726.531.0cfs ≈ 4.4×in -22.2bold=measured, italic=fitJun 19Jun 20Jun 21Jun 22Jun 23Jun 24Jun 25Picovale meter (cfs)Water orders (cfs)Gate setting (in)

2. North Ditch Gate Setting

DateTimeGate (in)ChangeSet by
2026-06-2405:1810.5Raised from 8.5″ currentHenry
2026-06-2209:358.5Raised from 8.1″Henry
2026-06-2205:348.1Raised from 7″Henry
2026-06-2010:157Raised from 6.1″Henry
2026-06-2005:326.1Raised from -1″Henry

3. Water Orders

SourceCFSEffective startEffective endNotes
AKT152026-06-22 07:00ongoingStands until changed
Bear River92026-06-24 07:00ongoingStands until changed

Current standing orders total 24 cfs. Orders are due 24 h ahead of a 7am delivery.

4. Picovale Meter Level

At an unchanged 10.5″ gate, flow is holding near 23.2 cfs (24-h average), running about 0.8 cfs under the 24 cfs order. Selected hourly readings (full series in master.csv):

DateTimecfsDiverted (AF)Note
2026-06-2501:0022.701.876
2026-06-2502:0023.801.967
2026-06-2503:0024.101.992
2026-06-2504:0023.401.934
2026-06-2505:0023.101.909
2026-06-2506:0021.301.760Latest latest

Prior full day (6/24) diverted 41.8 AF over 24 hours.

5. Gate → Meter Response

The gate is at 10.5″ (set 6/24). Recent daily-average flow: 7.7 (6/21), 12.5 (6/22), 14.6 (6/23), 21.1 (6/24), 22.9 (6/25). The 24-h mean is 23.2 cfs with scatter min 21.3, max 25.2, SD 0.8 — supply is running about 0.8 cfs under the 24 cfs order.

Calibration: at the current 10.5″ the rating point is 10.5″ → 23.2 cfs (n=22). Fit: cfs ≈ 4.4×in -22.2, so 24 cfs → ~10.4″. The website gate calculator uses this regression.

6. Weekly Shareholder Notes

Space reserved for weekly notes to shareholders — announcements, reminders, or items for the next meeting. (Add notes here before publishing.)